Fig.7-6 Comparison between (a) the test observation at the crown part of the elbow and (b) the analytical result using finite element analysis

Fig.7-6 Comparison between (a) the test observation at the crown part of the elbow and (b) the analytical result using finite element analysis

(a) A crack in the axial direction was observed at the crown part of the elbow. (b) The test result was reproduced well by finite element analysis.