4-6

Fig.4-6 Electrical conductivity of the solution within the crevice in 288 ℃ pure water with dissolved oxygen concentration of 32 ppm

The sensor at the smallest crevice gap detected high electrical conductivity of the crevice solution. Localized corrosion occurred in the vicinity of this position.