Fig.1-15  Temperature profile in LIVE-J1 experiment*

The temperature profile of LIVE facility used to simulate the lower head of an RPV is shown. The preloaded solid simulant materials began melting in the lower region of the debris bed to form a molten pool, which developed both upwards and horizontally.