Fig.8-13

Fig.8-13  Flammability test equivalent to the UL94 standard 5V

(a) The sample was fixed horizontally and burned intermittently from below with a flame height of 125 mm. (b) After releasing the burner, the sample self-extinguished within 1 s with a maximum damage range of 63 mm. (c) After releasing the burner, the sample self-extinguished within 1 s with a maximum damage range of 73 mm.