8-4 Influence of Distant Earthquakes upon Groundwater Flow

-A Case Study in the Tono Area-

Fig.8-10  Locations of the study area and monitoring

Fig.8-10 Locations of the study area and monitoring boreholes

Groundwater-pressure monitoring has been conducted in boreholes with depths ranging from several meters to approximately 1000 m in the study area. This study uses monitoring data from the DH-9, MIU-3, and AN-1 Boreholes.

 

Fig.8-11  Example of groundwater-pressure change

Fig.8-11 Example of groundwater-pressure change by an Earthquake (MIU-3 borehole)

This figure shows the monitoring results in the MIU-3 Borehole. The borehole intersects the Tsukiyoshi Fault at a depth of 700 m. Groundwater pressure in the southern part of the fault is monitored in sections No.1 and No.4. Groundwater pressure in the northern part of the fault is monitored in sections No.6 and No.8. At the south of the fault, the groundwater pressure decreased after earthquakes. In contrast, at the north of the fault, the groundwater pressure increased following earthquakes.

 

Fig.8-12  Example of hydraulic-gradient change by an earthquake

This Picture(108KB)

Fig.8-12 Example of hydraulic-gradient change by an earthquake (between the DH-9 and MIU-3 Boreholes)

This figure shows the change in the hydraulic gradient after earthquakes. After earthquakes with magnitudes of 7 to 8 (shown as (1) – (3) in the figure), the hydraulic gradient temporarily changed and was then restored with time before the earthquake. On the other hand, after the magnitude-9 earthquake (4), the hydraulic gradient changed but was not restored before the earthquake. The change in the hydraulic gradient during earthquake (5), whose epicenter is close to the study area, did not recover before the earthquake, too.

 


For geological disposal for high-level radioactive waste, evaluating the groundwater-flow condition is important. Therefore, evaluating the groundwater-pressure change is necessary because this distribution and its change help to control groundwater flow. Long-term groundwater-pressure monitoring has been conducted in our field of study (Fig.8-10), and it was found that groundwater-pressure changes as a result of earthquakes. The earthquakes that changed pressure include (1) the Tokachi-oki earthquake of 2003, (2) the earthquake off the coast of Kii Peninsula in 2004, (3) the Suruga Bay earthquake in 2009, (4) the 2011 earthquake off the Pacific coast of Tohoku, (5) the earthquake in the east of Mino in 2011, (6) the earthquake on the west coast of northern Sumatra in 2012, and (7) the earthquake off the Sanriku coast in 2012. Groundwater-pressure changes after each earthquake differed in each monitoring section. However, the changes all occurred in the same direction (increase or decrease) over the same monitoring section (Fig.8-11).

The change in hydraulic gradient differs depending on the magnitude or the distance between the epicenter and the monitoring point for each earthquake (Fig.8-12). Therefore, we will continue long-term groundwater-pressure monitoring to confirm changes in the hydraulic gradient.

These results show that it is important to focus on not only the change in groundwater pressure but also that in the hydraulic gradient in evaluating the long-term stability of the groundwater-flow condition.


 |